GIM500R - 1-dimensional - Inclination sensor
GIM500R - 1-dimensional - Inclination sensor Technical data - electrical ratings Voltage supply 8...36 VDC Reverse polarity protection Yes Short-circuit proof Yes Consumption w/o load ?40 mA (24 VDC) Initializing time ?1 s after power on Interface CANopen® SAE J1939 Analog (4...20 mA, 0...5 V or 0...10 V) Measuring range 0...90°, 0...120°, 0...180°, 0...270°, 0...360° Load resistor ?1 k? / voltage output ?800 ? / current output Resolution 0.025 ° Accuracy (+25 °C) Typ. �0.1° Temperature coefficient 0.008 °/K Repeatability 0.1 ° (+25 °C) Sensing rate 800 Hz Limit frequency 0.1...25 Hz, 2. order / low-pass filter (Default: 5 Hz) Interference immunity DIN EN 61000-6-2 ECE Reg. No. 10R04 ISO 7637-2 ISO 11452-2 / ISO 11452-5 Emitted interference DIN EN 61000-6-4 ECE Reg. No. 10R04 ISO 7637-2 / EN 55025 Programmable parameters Preset and offset Filter Diagnostic function Parameter error Status indicator DUO-LED integrated in housing Approval UL approval / E63076 Technical data - mechanical design Dimensions W x H x L 48 x 24 x 52 mm Protection DIN EN 60529 IP 66 IP 67 IP 68 IP 69K Material Housing: aluminium, coated Corrosion protection IEC 60068-2-52 Salt mist Complies to ISO 12944-5:1998 Protective paint systems (C5-M) Operating temperature -40...+85 °C (see general information) Resistance DIN EN 60068-2-6 Vibration �1.5 mm - 10-58 Hz 20 g - 58-2000 Hz DIN EN 60068-2-27 Shock 200 g, 6 ms Weight approx. 95 g Connection Flange connector M12, 8-pin Flange connector M12, 5-pin Cable 1 mVisit the Greenbank Machinery and Plant Ltd website for more information on GIM500R - 1-dimensional - Inclination sensor